Does Detailed sensitivity recover short MIDI notes?
Not every time. In this controlled isolated-C4 check, 50 and 55 ms produced no event at any setting. At 60 ms, Balanced and Detailed retained one event while Clean did not.
Controlled sensitivity check
| One isolated C4 | Clean | Balanced | Detailed |
|---|---|---|---|
| 50 ms | 0 retained; 1 missed | 0 retained; 1 missed | 0 retained; 1 missed |
| 55 ms | 0 retained; 1 missed | 0 retained; 1 missed | 0 retained; 1 missed |
| 60 ms | 0 retained; 1 missed | 1 retained; 0 missed | 1 retained; 0 missed |
Use a setting change as a test, not a repair
Clean requires four adjacent analysis frames, Balanced requires three, and Detailed requires two. If Detailed changes a source-backed event while the broader melody stays right, keep that result. If the source is a chord, noisy onset, or full mix, changing sensitivity does not turn it into a separate melody line.
Fixture conditions and limits
Each point used 10 generated mono 44.1 kHz 16-bit PCM WAV fixtures, a
synthetic voice-like harmonic C4 source, Melody / solo instrument mode,
a 2048-sample analysis window, and a 1024-sample hop. A retained note
required exactly one output within 50 cents and with at least 50%
overlap. Detector SHA-256:
DDA185AC8FB6A179A4FCFA73FD4197ACC95B8B6F59B233F5D3E330F596309F9F.
These are controlled source checks, not a universal sensitivity, voice, instrument, song, or accuracy promise.