Does high-pass filtering affect MIDI conversion?
Not in this controlled eight-note fixture. One-pole high-pass cutoffs from 200 Hz through 1,600 Hz retained all eight notes with zero median misses and extra events.
Controlled high-pass check
| One-pole high-pass cutoff | Median across 10 fixtures |
|---|---|
| 0, 200, 400 Hz | 8 retained; 0 missed; 0 extra |
| 800, 1,600 Hz | 8 retained; 0 missed; 0 extra |
What this result leaves open
A high-pass filter removes low-frequency energy but this short C4/E4 harmonic fixture still supplied enough periodic information for the detector. It does not test bass-only material, a full mix, or a recording with noise and competing instruments.
Fixture conditions and limits
Each point used 10 mono 44.1 kHz synthetic PCM fixtures with eight
alternating C4/E4 voice-like harmonic notes, 120 ms per note, 0.70
source amplitude, and an 8 ms fade. Only the one-pole high-pass cutoff
changed. Melody / solo instrument mode, Balanced sensitivity, a
2048-sample analysis window, and a 1024-sample hop stayed fixed.
Retained means exactly one output overlaps at least 50% and is within 50
cents. Detector SHA-256:
DDA185AC8FB6A179A4FCFA73FD4197ACC95B8B6F59B233F5D3E330F596309F9F.
These are controlled source checks, not a universal filtering or accuracy promise.